Relays are devices making or breaking electric circuits by their output section driven by operational signal, which is triggered by electric input signal controlled by switching devices.
Manufacturer
Omron Automation and Safety
Manufacturer Product Number
LY2-AC24
Description of Omron Relay LY2 AC24
RELAY GEN PURPOSE DPDT 10A 24V
Bi-power Relay, 2-pole, Single contact, Plug-in Terminals, 24 VAC
Coil ratings 24 VAC 50 Hz 53.8 mA
24 VAC 60 Hz 46 mA
Contact form DPDT
Contact method Single
Contact material Ag alloy
Contact rated load 10 A (Resistive load)
110 VAC 7.5 A (Inductive load (cosφ = 0.4))
24 VDC 10 A (Resistive load)
24 VDC 5 A (Inductive load (L/R = 7 ms))
Terminal structure Plug-in terminal
Performance
Contact resistance 50 mΩ max. (Voltage drop method with 5 VDC 1 A)
Operating time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Reset time 25 ms max. (With rated operating power applied, 23 ℃, not including contact bounce)
Maximum operating frequency Mechanical: 18000 time/hour
Rated load: 1800 time/hour
Insulation resistance Between coil and contacts: 100 MΩ min. (at 500 VDC)
Between contacts of same polarity: 100 MΩ min. (at 500 VDC)
Between contacts of different polarity: 100 MΩ min. (at 500 VDC)
Dielectric strength Between coil and contacts: 2000 VAC 50/60 Hz 1 min
Between contacts of same polarity: 1000 VAC 50/60 Hz 1 min
Between contacts of different polarity: 2000 VAC 50/60 Hz 1 min
Vibration resistance (destruction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Vibration resistance (Malfunction) 10 to 55 to 10 Hz, 0.5-mm single amplitude (1-mm double amplitude)
Shock resistance (destruction) 1000 m/s2
Shock resistance (Malfunction) 200 m/s2
Endurance (Mechanical) 50 million operations min. (switching frequency 18,000 operations/h)
Failure rate 100 mA at 5 VDC (failure level: Preference value, Switching frequency: 120 operations per minute)
Ambient temperature (Operating) -25 to 55 ℃ (with no freezing or condensation)
Ambient humidity (Operating) 5 to 85 %
Weight Approx. 40 g
Mounting method Socket
Applicable socketPTF-08-PU/ PTF-08-PU-L/ PTF08A/ PTFZ-08-E/ PT08/ PT08QN/ PT08-0
LY1 AC100/110;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 100/110 VAC
LY1 AC110/120;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 110/120 VAC
LY1 AC12;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 12 VAC
LY1 AC200/220;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 200/220 VAC
LY1 AC24;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 24 VAC
LY1 DC100/110;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 100/110 VDC
LY1 DC12;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 12 VDC
LY1 DC24;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 24 VDC
LY1 DC48;
Bi-power Relay, 1-pole, Single contact, Plug-in Terminals, 48 VDC
LY1-0 AC100/110;
Bi-power Relay, 1-pole, Single contact, PCB Terminals, 100/110 VAC
LY1-0 AC110/120;
Bi-power Relay, 1-pole, Single contact, PCB Terminals, 110/120 VAC
LY1-0 AC200 ;
Model Number Description
LY3 DC12;
Bi-power Relay, 3-pole, Single contact, Plug-in Terminals, 12 VDC
LY3 DC24;