Roxar 2600 MPFM MVG: Impedance, Venturi and Gamma Density measurements; single or multi-well applications; full range of oil, water and gas flow rates; 0 % to 100 GVF; 0 % to 100 WLR; flow rate: 1 to 40 m/s
The technical parameters of the Roxar 2600 MPFM MVG are as follows:
Measurement range
Gas volume fraction (GVF): 0 - 100%
Liquid water ratio (WLR): 0 - 100%
Flow rate: 1 - 40m/s
Instrument size: 1.5 inches (35mm) to 8 inches (173mm) inside diameter, different sizes correspond to different design pressures and application scenarios.
Design pressure: up to 5,000 psi (345 bar).
Design temperature: -4°F (-20°C) to 266°F (130°C), lower minimum temperatures can be evaluated and adapted according to specific circumstances.
Process contact materials: including duplex stainless steel UNS S31803, stainless steel UNS S31600, super duplex stainless steel UNS S32760, Inconel alloy 625 UNS N06625, polyetheretherketone (PEEK), etc.
Flange connection: ANSI flange or hub with clip-on connector.
Gamma measurement (where applicable): Compact gamma system with Cs-137 source, 2mCi, 5mCi or 8.3mCi, 30.1 year half-life.
Power supply: 18 - 30 VDC or 100 - 240 VAC, power consumption less than 20W.
Communication protocols: Modbus RTU, Modbus TCP, HTTP.
Communication interfaces: RS-485, Ethernet.
Mounting: Vertical upward mounting.
Certifications: ATEX, IECEx, CSA C/US, EAC, etc., designed in accordance with ASME B16.5 and ASME B31.3 standards, materials in accordance with ASME B31.3 specifications, parts in contact with corrosive media in accordance with NACE MR0175 and ISO 15156 standards.
Measurement Uncertainty: Under 95% confidence interval, the relative uncertainty of gas flow measurement corresponding to different ranges of GVF is: 7.0% when less than 25%; 5.0% for 25 - 90%; 5.0% for 90 - 95%; 5.0% for 95 - 98%; and 5.0% for greater than 98%. The relative uncertainty of liquid flow measurement is 1/4 of the liquid flow, and the absolute uncertainty of water-to-liquid ratio measurement is 1/4 of the water-to-liquid ratio (under given conditions, such as operating pressure above 73 psi (5 bar), and requires correct PVT and water conductivity input).