Accuracy
Rod probe:+/- 2 mm (0.08 in)
Process temperature
-20...+150 °C
(-4...+302 °F)
Process pressure / max. overpressure limit
Vacuum...16 bar
(Vacuum...232 psi)
Max. measurement distance
Rod: 6 m (20 ft)
Min DK>1.6
Main wetted parts
Rod probe:
304, 304L, 316L, PEEK
Levelflex FMP53 for continuous level measurement for hygienically sensitive applications in the food and life sciences industry. FMP53 meets the hygiene requirements according to ASME BPE and USP Class VI. The unique in situ validation without dismantling from the process is a cost saving advantage. FMP53 guided radar offers maximum reliability even in case of moved surface and foam, for changing medias and in case of filling via spray head.
Version with rod probe.
Process connections: For hygiene requirements (Tri-Clamp, 11851, 11864, NEUMO,
Varivent N, SMS)
Temperature: -20 to +150°C (-4 to +302°F)
Pressure: -1 to +16bar (-14.5 to +232psi)
Maximum measuring range: Rod 6m (20ft)
Accuracy: ±2mm (0.12")
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates, 5-point linearity protocol
Reliable measurement even for changing product and process conditions
HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics
Highest reliability due to new Multi-Echo Tracking evaluation
Hardware and software developed according to IEC 61508 up to SIL3
Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle
Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)
World's easiest proof test for SIL and WHG saves time and costs
Guided radar measurement Time-of-Flight Levelflex FMP51
Guided radar measurement Time-of-Flight Levelflex FMP52
Guided radar measurement Time-of-Flight Levelflex FMP53
Guided radar measurement Time-of-Flight Levelflex FMP54
Guided radar measurement Time-of-Flight Levelflex FMP55
Guided radar measurement Time-of-Flight Levelflex FMP56
Guided radar measurement Time-of-Flight Levelflex FMP57