MIDAS-E-HCL
The parameters of Honeywell Analytics MIDAS-E-HCL are as follows:
Measurement range: 0 - 8ppm, can detect gases such as hydrogen chloride (HCl), boron trichloride (BCl₃), dichlorosilane (H₂Cl₂Si) and hydrogen bromide (HBr), and the measurement range is 0.72 - 8ppm.
Measurement accuracy: ±5%FS.
Resolution: 0.01ppm.
Sensitivity: Typical value is 0.05ppm/ppm (at 20℃).
Repeatability: <±10% of measured value.
Linearity: <±20% of measured value.
Response time: T₆₂.₅ <30 seconds (based on 3 minutes exposure), T₉₀ <140 seconds (based on 3 minutes exposure).
Operating temperature: 0℃ - 40℃ (32°F - 104°F).
Operating humidity: 20% - 75%RH (continuous).
Operating pressure: 90 - 110kPa.
Power supply: 24V DC (-15% to +10%), 208mA.
Output signal: 3 alarm relays, 1A@30VDC or 0.5A@125VAC; 4 - 20mA@250Ω.
Warm-up time: <20 minutes.
Sensor life: 24 months under typical application conditions.
Dimensions: Transmitter dimensions (unit with sensor) 120 mm high, 63 mm wide, 150 mm thick; (low temperature version) pyrolyzer dimensions 70 mm high, 63 mm wide, 83 mm thick; (high temperature version) pyrolyzer dimensions 113 mm high, 101 mm wide, 140 mm thick.
Weight: Transmitter weight (unit with sensor) 0.8 kg; (low temperature version) pyrolyzer weight 0.41 kg; (high temperature version) pyrolyzer weight 1.25 kg.
Protection class: NEMA 1.
Certification: ETL, CE.