Yokogawa Zirconia Oxygen Humidity Analyzer ZR22G, ZR802G
The built-in heater assembly of the probe can be replaced on site, reducing maintenance costs.
The probe uses a long-life, high-reliability Zirconia sensor.
The probe uses three-reference gas supply methods (natural air convection, instrument air, and pressure compensated) in its applications.
The converter incorporates the LCD touchscreen for ease of operation.
Converter of Zirconia Oxygen Humidity Analyzer ZR22G ZR802G
This converter can be used as an oxygen analyzer as well as a high temperature humidity analyzer.
The deterioration status of the sensor can be confirmed by the sensor resistance check function (self-diagnosis function) in the converter.
The converter records history of alarm on/off, measured value history for up to 40 days, and others.
The integrated type integrates both probe and converter, to reduce wiring, piping, and installation costs. This type of unit uses an optical switch for ease of operation at the site.
Remote maintenance using digital communications (HART, Modbus TCP and RTU) reduces maintenance costs.
Application of Zirconia Oxygen Humidity Analyzer ZR22G ZR802G
Large or small/medium-sized boilers (for electric power, heavy oil, gas and coal, etc.)
Various industrial furnaces (oil / steel heating furnaces, coal kilns, etc.)
Zirconia Humidity at high temperatures Analyzer
Coloring process of textile factory
Steam curing process for concrete products
Various manufacturing and drying processes for building materials, wood, food, etc.
Various manufacturing and humidification processes for food products, etc.
General Purpose Specifications of Zirconia Oxygen Humidity Analyzer ZR22G ZR802G
Measurement Object Oxygen analyzer: Oxygen concentration in combustion exhaust gas and mixed gas
Humidity Analyzer: Water vapor (in vol%) in mixed gases (air and water vapor)
Measurement System Zirconia System (Detector ZR22G)
Measurement Range O2: 0.01–100 vol%
H2O: 0–100 vol%
Mixture ratio: 0–1.000 kg/kg
Digital Communication HART7 (AO1, 250 to 550 Ω)
Ethernet (Modbus TCP)
RS-485 (Modbus RTU)
Yokogawa oxygen analyzer ZR22G
Models: ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06
Yokogawa Separate type Zirconia Oxygen Analyzer ZR22G ZR22G, ZR22S, ZR402G, ZR22P, ZR22R, ZR22V, AC1, MC1, M1233SR, IAC-24, WZ-H, M1234SE-A, M1200DB-06
ZR22G-100-S-A-C-T-T-E-A, ZR22G-040-S-A-E-T-T-E-A/CV,
ZR402G-T-E-E-A, ZR22G-040-S-A-E-T-T-E-A,
ZR22G-070-S-A-E-T-T-E-A, ZR402G-T-E-E-A/SCT,
ZR40H-T-T-AK9473XJ, ZR22G- 070-S-A-E-T-T-E-A,
ZR402G- T-E-E-A, ZR402G-T-E-E-A,
ZR22G-070-S-A-E-T-T-E-A, ZR22G-070-S-A-E-T-T-E-A,
ZR402G-M-E-E-A/SCT, ZR22G-150-S-A-E-T-M-E-A/SCT,
ZR22G-040-S-A-C-T-T-E-A, ZR22G-040-S-A-C-T-T-E-A/SCT,
ZR22G-040-S-A-E-T-T-E-A, ZR402G-T-E-E-A,
ZR40H-T-T-A, ZR22G-040-S-A-C-T-T-E-A,
ZR22G-100-S-C-T-T-E-A, ZR402G-M-E-E-A,
ZR40H-T-T-A, ZR402G-M-E-E-A/H/SCT,
ZR22G-040-C-C-C-T-T-E-A, ZR40H-T-T-A,
ZR22G-040-S-A-C-T-T-E-A, ZR402G-T-E-E-A,
ZR22G-070-S-A-E-T-T-E-A, ZR22G-070-S-A-E-T-T-E-A/CV/F1/SCT,
ZR22G-100-S-A-E-T-M-E-A, ZR402G-M-E-E-A/SCT,
ZR22G-100-S-B-E-T-T-E-A,