Specs at a glance
Accuracy
Standard 0.2%
Optional 0.1%
Process temperature
-10°C...100°C
(14°F...212°F)
Pressure measuring range
100 mbar...10 bar
(1.5 psi...150 psi)
Process pressure / max. overpressure limit
40 bar (600 psi)
Main wetted parts
Alloy C
316L
optional coating AuPt
Max. measurement distance
100m (328ft) H2O
Material process membrane
316L, AlloyC
Gold-Rhodium
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications.
It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
For level and/or pressure measurement.
Process connections: Thread, flanges and flush-mounted hygienic connections
Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)
Measuring range: 0.1 to 10bar (1.5 to 150psi)
Accuracy: ±0.2%, ±0.1% (option)
International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system integration (HART/PA/FF)
Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus
International usage thanks to a wide range of approvals
FMB50-AA21JD1MGDCGJB3U
FMB50-AA22QA1MGAUPJB3U
FMB50-AA21RA1CGAUPJB3U
FMB50-AA21RA1CGAUPJB3U+AC
FMB50-AA21JA1HGBCFJB3U
FMB50-AA21RA1MGBUPJB3U