Specs at a glance
Measuring range
Conductivity:
0 µS/ cm...100 mS/ cm
Build-up thickness:
0 mm…10 mm
Process temperature
-20°C…+100°C
(-4°F...+212°F)
+150°C (+302°F) for 1h
Process pressure
Vacuum...25 bar
(Vacuum...362.5 psi)
Measuring method
Capacitive- conductive
The Liquitrend QMW43 is developed for the food and beverage industry to help customers to ensure product safety, improve quality and increase the availability of installations. Base your decisions on the unique and reliable measurement of buildup thickness and conductivity via the combination of conductive and capacitive measuring modes.
Cleaning optimization, blending homogeneity monitoring and media differentiation of liquids, suspensions, pasty media etc.
For the use in storage, mixing and process vessels with or without an agitator, pipes and equipment periphery
Process connections: Threads and hygienic connections
Sensor design: Flush-mounted, surface roughness Ra<0.76µm
Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour
Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204- 3.1
Reliable, repeatable and accurate measurement of buildup thickness and conductivity regardless of media type
Conductive as well as capacitive measuring cycles, the device automatically detects the most accurate measuring mode and uses it automatically
Verification of cleaning status without the need to open the tank
Compact and flush-mounted stainless-steel sensor offers the perfect insight into the conditions in pipelines or tanks at all critical locations
Plug and Play - simple commissioning without presettings
Hygienic safety by Design and material traceability are a matter of course
Integrated digital communication option via IO-Link
Cleaning optimization, blending homogeneity monitoring and media differentiation of liquids, suspensions, pasty media etc.
For the use in storage, mixing and process vessels with or without an agitator, pipes and equipment periphery
Process connections: Threads and hygienic connections
Sensor design: Flush-mounted, surface roughness Ra<0.76µm
Temperature: -20 to +100°C (-4 to +212°F), CIP/SIP to 150°C (302°F) for 1 hour
Certificates and declarations: 3A, FDA, EHEDG and EG1935/2005, EN10204- 3.1
Digital conductivity sensor Memosens CLS15E
Digital conductivity sensor Memosens CLS16E
Digital conductivity sensor Memosens CLS21E
Digital 4-electrode conductivity sensor Memosens CLS82E
Analog conductivity sensor Condumax CLS12
Analog conductivity sensor Condumax CLS13
Analog conductivity sensor Condumax CLS15
Analog conductivity sensor Condumax CLS16B
Analog conductivity sensor Condumax CLS19
Analog conductivity sensor Condumax CLS21