Welcome to CW Green Tech Limited
[email protected] 86-136 6712 1125
Home      Products TTH200Y0HBS ABB TTH200 Head-Mount Temperature Transmitter
TTH200Y0HBS ABB TTH200 Head-Mount Temperature Transmitter

TTH200Y0HBS ABB TTH200 Head-Mount Temperature Transmitter

  • Product Item : TTH200Y0HBS
  • Product Brand : ABB
  • INQUIRY

Head-mount temperature transmitter TTH200, TTH200Y0HBS ABB TTH200 Head-Mount Temperature Transmitter

The new temperature transmitter TTH200 supports both the HART 5 and HART 7 protocol and is the standard device of the proven TTx200 / TTx300 product family in two-wire technology. The TTH200 is provided for all HART standard applications in temperature measurement with one sensor input. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. The TTH200 supports the same functionality as the TTH300, but without sensor redundancy and sensor drift monitoring. As an option, an LCD indicator can be connected. The transmitter can be configured with ABB-tools such as Field Information Manager (FIM), with DAT200 (Asset Vision Basic) via DTM, with a Handheld via EDD, or with any standard tool using FDI-/FDT-Technology.


Specification of TTH200Y0HBS ABB TTH200 Head-Mount Temperature Transmitter

Part Number: TTH200Y0HBS

Model: TTH200 Head-Mount Temperature Transmitter

Brand: ABB

Condition: New & Original in Factory Packing

Factory Warranty: 12 Months

Ordering Information

Base Model TTH200 TTH200 Head Mounted Temperature Transmitter, HART, Pt100 (RTD), thermocouples, electrical isolation

Explosion Protection Y0 Without explosion protection

Communication Protocol H HART, programmable, output signal 4 to 20 mA

Configuration BS Standard configuration


Applications: Temperature measurement in air, soil, or water, measurement of delicate surfaces (e.g., leaves, fruits), Oil, Gas and Petrochemical, Research and Development,  Hazardous Areas.


ABB TTH200 Head Mounted Temperature Transmitter is a device used to convert the signal from a temperature sensor (like a thermocouple or RTD) into a standardized output signal, usually 4-20 mA or a digital hart protocol, designed for industrial applications, offering precision and reliability in temperature measurement, The TTH200 is also called as Thermocouple Transmitter. This High-Range Temperature Transmitter is provided for all HART standard applications. ABB TTH200 Head Mounted Temperature Transmitter is designed for standard type B sensor heads. The ABB TTH200 is provided for all HART standard applications in temperature measurement with a single sensor. This Head Mount Temperature Sensor can support the functionality as same as ABB TTH 300 Temperature Transmitter but the difference is that without sensor drift and sensor redundancy monitoring that can be configured via any standard FTD tool via EDD or FDT / DTM in DAT200 (Asset Vision Basic).



Features Of Head-Mounted Temperature Transmitter:


  • This 4 20ma temperature sensor is HART Compatibility

  • ATEX, IECEx, Zone 0 Compliance

  • The TTH200 meets all requirements for the CE mark by IEC 61326 (2006)

  • Conforms with IEC 61508 as regards use in safety-related applications, up to and including SIL 2.

  • This temperature transmitter 4 20ma is Event monitor for logging critical events

  • Universal sensor input for resistance thermometers (RTD) and thermocouples


More Models related to ABB TTH200 Head Mounted Temperature Transmitter:


TTH300-E1H; TTH300-Y0-H-BS-M; TTH300-E1-H-BS-M; TTH300-E2-H-BS-M; TTH200-Y0S2A1A02A4Y0N1S1P2B2B2H6/OPT;

TTH200-E1; TTH200-E1HBFEMGHAM5; TTH200-E1HBFEMD3SF; TTH200.Y0.H.BS; TTH200-E1-H-BS;TTH200-E1HBFE;

TTH200-Y0-H-BS/M5.SF; TTH200-E1; TTH200-Y0-H-BS/M5.SF; TTH200-E1-H-BS-C6-EM-GHA-M5; TTH200-C1-H-BS-C6-EM-GHA-M5;

TTH200 Y0-H-BS-M5; TTH200-E1-H-BS-C6-EMGHA-M5; TTH200-E1-H-BS; TTH200-E1H - PTB05 ATEX 2017X; TTH200.Y0.H.BS;

TTH200-E1H - PTB05 ATEX 2017X; TTH200-Y0-H-B5-CS-EM-GHE-H1-D3-M5; TTH200.E1.H.BF.CS.EM.GHA.D3; TTH200-Y0S2A1A02A4Y0N1S1P2B2B2H6/OPT; TTH200-C1-H-BS-C6-EM-CHA-M5;

TTH200.E1.H.BF.CS.EM.GHA.D3SFM5; TTH200E1HBFEMGHAM5; TTH200-C1-H-BS-C6-EM-CHA-M5; TTH200-E1-H-BS-CS-EM-SE-M5; TTH200-C1-HBS-C6-EM-CHA-M5;

TTH200-E1-H-BS; TTH200-E1-H-BS-CS-EM-SE-M5, PT100, 3 WIRE HART; TTH200E1; TTH200-E1-H-BS-C6-EM-GHA-M5; TTH200-E1;

TTH200.Y0.H.BS.D3; TTH200.Y0.H.BS; TTH200Y0HBFEMGHEM5; TTH200-Y0; TTH200.E1.H.BF.CS.EM.GHA.D3.SF.M5;

TTH200-Y0-H-BS-M5; TTH200.E1.H.BF.EM.D3.SF; TTH200-E1-H-BS-CS-EM-GHE-M5; TTH200-E1H-PTB 05 ATEX 2017 X; TTH200.YO.H.BS;

TTH200.Y0.H.BS; TTH200-E1 , HART; TTH200-C1-H-BS-C6-EM-CHA-M5; TTH200.Y0.H.BS; TTH200-C1-H-BS-C6-EM-CHA-M5; TTH200-C1-H-BS-C6-EM-CHA-M5;

TTH200-Y0-H-BS-CS-EP-GHA-H7-D3-SF-M; TTH200.E1/OPT; TTH200-Y0HBS-EM.M5; TTH200Y0H+7C201; TTH200 Y0;

TTH200.E1.H.BF.CS.EM.GHA..D3.SF.M5; TTH200-YO/OPT; TTH200.E1.H.BF.CS.EM.GHA.D3SFM5; TTH200-Y0-H-BS; TTH200-E1.H;

TTH200-C1-H-BS-C6-EM-GHA-M5; TTH200-E1/OPT (RTD WIRE ); TTH200.E1.H.BS; TTH200-C1-H-BS-C6-EM-CHA-M5; TTH200.E1.H.BF.CS.EM.GHA..D3.SF.M5;

TTH200.Y0-H-BS-M5; TTH200 E1 H BS CS EM SE M5; TTH200-S1.H; TTH200Y0H; TTH200-Y0-H-BS;