ABB TTR200 Rail-mount temperature transmitter

The TTR200 is a universal rail-mount HART temperature transmitter in a compact 17.5 mm housing. The transmitter provides increased device safety in compliance with NE89 and NE107 and hardware write protection.The TTR200 is a rail-mount version of the TTH200 transmitter with the addition of two indicator LEDs. A green LED indicates that the transmitter is powered. A red LED would indicate a fault in either the unit or the sensor. TTR200 units can be placed in cabinet racks. It can be configured with ABB-tools such as DAT200 (Asset Vision Basic) via DTM, Handheld via EDD, FIM (Field Information Manager) or any standard tool using FDI-/FDT-Technology.

Data of ABB TTR200 Rail-mount temperature transmitter

Universal sensor input

– RTD, thermocouple, Ω, mV

Functional safety SIL 2 / SIL 3 in accordance with IEC 61508

Output signal

– 4 to 20 mA, HART

Accuracy 0.1 %, long-term stability 0.05 % per year

Wire break / corrosion monitoring in accordance with NE 89

Diagnostic information in accordance with NE 107

Approvals for explosion protection

– ATEX, IECEx, zone 0

– FM / CSA

– GOST

Basic model: TTR200, with universal sensor input, can receive RTD, thermocouple, Ω, mV and other signals; output signal is 4-20mA, HART; accuracy is 0.1%, long-term stability is 0.05% per year; with wire break/corrosion monitoring in accordance with NE89 and diagnostic information in accordance with NE107; explosion-proof certification includes ATEX, IECEx, Zone 0, FM/CSA, GOST, etc.

Other commonly used models of ABB TTR200 Rail-mount temperature transmitter:

TTR200.E1.H.BF.CS.EM.GHA.Z9.M5: The specific meaning may involve a combination of different parameters such as explosion-proof level, communication protocol, configuration, etc.

TTR200.E1.H.BF.EP.CS.M5: It is also a specific model set according to different application requirements.

TTR200.Y0HBS: It may represent a standard configuration or a specific function combination.

TTR200E1HBFM5: Also a specific model variant in the TTR200 series.

For example, in TTR200E1HBS, "E1" may indicate that the explosion-proof level is Zone 1 (20): II 2G (1D) Ex (ia IIIC da) ib IIC T6 Gb; "H" indicates that the communication protocol is HART; "BS" indicates standard configuration.