  • Product Item : AX150-30-11-88 1SFL991074R8811
  • Product Brand : ABB
  • INQUIRY

Product model:

AX150-30-11-88

Product ID:

1SFL991074R8811

European Article Number (EAN):

7320500500194

Catalog description:

AX150-30-11-88 Contactor

Detailed description:

AX150-30-11-88 Contactor

Dimensions

Net width:102 mm

Net depth:123.5 mm

Net height:148 mm

Net weight:1.9 kg

Technical parameters

Number of main contacts NO:3

Number of main contacts NC:0

Number of auxiliary contacts NO:1

Number of auxiliary contacts NC:1

Number of poles:3P

Rated operating voltage:

Main Circuit 1000 V

Rated frequency (f):

Main Circuit 60 Hz

Rated thermal current (free air) (Ith):

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 190 A

Rated operating current AC-1 (Ie):

(690 V) 40 °C 190 A

(690 V) 55 °C 145 A

(690 V) 70 °C 130 A

Rated operating current AC-3 (Ie):

(415 V) 55 °C 150 A

(440 V) 55 °C 100 A

(500 V) 55 °C 100 A

(690 V) 55 °C 82 A

(380 / 400 V) 55 °C 150 A

(220 / 230 / 240 V) 55 °C 150 A

Rated operating power AC-3 (Pe):

(415 V) 75 kW

(440 V) 59 kW

(500 V) 59 kW

(690 V) 75 kW

(380 / 400 V) 75 kW

(220 / 230 / 240 V) 45 kW

Rated breaking capacity AC-3 in accordance with IEC60497-4-1:

8 x Ie AC-3

Rated making capacity AC-3 in accordance with IEC 60947-4-1:

10 x Ie AC-3

Rated uninterruptible current (Icw):

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A

at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A

Rated insulation voltage (Ui):

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V

Rated impulse withstand voltage (Uimp):

8 kV

Maximum electrical switching frequency:

300 cycles per hour

Mechanical life:

10 million

Maximum mechanical switching frequency:

3600 cycles per hour

Coil operating limit:

(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)

Rated control circuit voltage (Uc):

50 Hz 230 ... 240 V

60 Hz 240 ... 260 V

Power loss:

at Rated Operating Conditions per Pole 2.7 W

Protection class:

acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40

Terminal type:

Main Circuit: Bars

Product:

Block Contactor

Environmental conditions

Ambient temperature:

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C

Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C

Close to Contactor for Storage -40 ... 70 °C

Maximum operating altitude:

Without Derating 3000 m