General Information
Extended Product Type:
AX185-30-11-88
Product ID:
1SFL491074R8811
EAN:
7320500500262
Catalog Description:
AX185-30-11-88 Contactor
Long Description:
AX185-30-11-88 Contactor
Ordering
Minimum Order Quantity:1 piece
Customs Tariff Number:85364900
Instructions and Manuals:AX185~205A instructions
Dimensions
Product Net Width:111.5 mm
Product Net Depth / Length:162.3 mm
Product Net Height:196 mm
Product Net Weight:3.2 kg
Technical
Number of Main Contacts NO:3
Number of Main Contacts NC:0
Number of Auxiliary Contacts NO:1
Number of Auxiliary Contacts NC:1
Number of Poles:3P
Rated Operational Voltage:Main Circuit 1000 V
Rated Frequency (f):Main Circuit 60 Hz
Conventional Free-air Thermal Current (Ith):acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
Rated Operational Current AC-1 (Ie):
(690 V) 40 °C 250 A
(690 V) 55 °C 230 A
(690 V) 70 °C 180 A
Rated Operational Current AC-3 (Ie):
(415 V) 55 °C 185 A
(440 V) 55 °C 145 A
(500 V) 55 °C 145 A
(690 V) 55 °C 120 A
(380 / 400 V) 55 °C 185 A
(220 / 230 / 240 V) 55 °C 185 A
Rated Operational Power AC-3 (Pe):
(415 V) 90 kW
(440 V) 75 kW
(500 V) 90 kW
(690 V) 110 kW
(380 / 400 V) 90 kW
(220 / 230 / 240 V) 55 kW
Rated Breaking Capacity AC-3:
8 x Ie AC-3
Rated Making Capacity AC-3:
10 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw):
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
Rated Insulation Voltage (Ui):
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
Rated Impulse Withstand Voltage (Uimp):
8 kV
Maximum Electrical Switching Frequency:
300 cycles per hour
Mechanical Durability:
5 million
Maximum Mechanical Switching Frequency:
3600 cycles per hour
Coil Operating Limits:
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc):
50 Hz 230 ... 240 V
60 Hz 240 ... 260 V
Power Loss:
at Rated Operating Conditions per Pole 5 W
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Terminal Type:
Main Circuit: Bars
Product Name:
Block Contactor
Environmental
Ambient Air Temperature:
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible:
Without Derating 3000 m