The technical parameters of Fisher 67CFSR-224 are as follows:
Basic parameters
Type: Stainless steel instrument supply regulator with filter and internal pressure relief
Spring box style: 1/4 NPT
Adjusting screw: Square head with closed cap
Second outlet: Plug with pipe plug
Pressure parameters
Inlet pressure: Maximum inlet pressure (valve body rating) 250 psig (17.2 bar)
Outlet pressure: Outlet pressure range 0-150 psig (0-10.3 bar); maximum emergency outlet pressure is 50 psig (3.4 bar) above outlet pressure
Smart bleed set point: 6 psi (0.41 bar) pressure difference
Flow coefficient
Main valve flow coefficient: C=11.7
Internal pressure relief valve flow coefficient: Cg=0.045
Accuracy parameters
Inlet sensitivity: Outlet pressure change is less than 0.2 psig (14 mbar) for every 25 psig (1.7 bar) inlet pressure change
Repeatability: 0.1 psig (7 mbar)
Temperature Range
Using Nitrile (NBR) standard bolts: -20°F to 180°F (-29°C to 82°C)
Using Stainless Steel Bolts: -40°F to 180°F (-40°C to 82°C)
Using Fluorocarbon (FKM): 0°F to 300°F (-18°C to 149°C)
Using Silicone (VMQ): -60°F to 180°F (-51°C to 82°C)
Weight: Approximately 4 lbs (1.8 kg)
Filter Capacity
Free Area: 12 times the area of the pipe
Micron Rating: 5 micron for standard polyethylene filter; 5 micron for optional fiberglass filter, 40 micron for optional polyvinylidene fluoride (PVDF) or stainless steel filter