WAGO 750-363 Fieldbus Coupler EtherNet/IP 750-363 I/O System PLC Module
Communication EtherNet/IPTM
ETHERNET protocols HTTP(S)
BootP
DHCP
DNS
SNTP
FTP(S)
SNMP
Baud rate 10/100 Mbit/s
Transmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5; 100 m maximum cable length
Transmission performance Class D per EN 50173
Number of modules per node (max.) 250
Number of modules without a bus extension (max.) 64
Configuration options WAGO-I/O-CHECK
Web-Based Management
Input and output process image (fieldbus) max. 1020 words/1020 words
Supply voltage (system) 24 VDC (-25 … +30 %); via pluggable connector
Current consumption (5 V system supply) 350mA
Total current (system supply) 700mA
Input current (typ.) at nominal load (24 V) 280mA
Power supply efficiency (typ.) at nominal load (24 V) 90%
Isolation 500 V system/field
Indicators LED (LINK/ACT) green: Network connection via ports 1 … 2; LED (MS, NS) red/green: Status of node, network; LED (I/O) red/green/orange: Status of local data bus
Connection data of WAGO 750-363 Fieldbus Coupler EtherNet/IP 750-363 I/O System PLC Module In Stock
Connection technology: communication/fieldbus EtherNet/IPTM: 2 x RJ-45
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: device configuration 1 x Male connector; 4-pole
Connection type 1 System supply
Solid conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 2.5 mm² / 28 … 14 AWG
Strip length 8 … 9 mm / 0.31 … 0.35 inches
Physical data
Width 49.5 mm / 1.949 inches
Height 96.8 mm / 3.811 inches
Depth 71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail 64.7 mm / 2.547 inches
Mounting type DIN-35 rail
Material Data
Housing material Polycarbonate; polyamide 6.6
Fire load 1.407MJ
Weight 104.1g
Environmental requirements
Ambient temperature (operation) 0 … +55 °C
Ambient temperature (storage) -25 … +85 °C
Protection type IP20
Pollution degree 2 per IEC 61131-2
Operating altitude 0 … 2000 m / 0 … 6562 ft
Mounting position horizontal (standing/lying); vertical
Relative humidity (without condensation) 95%
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference per EN 61000-6-2, marine applications
EMC emission of interference per EN 61000-6-3, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible pollutant concentration H2S at a relative humidity < 75% 10ppm
Permissible pollutant concentration SO 2 at a relative humidity < 75% 25ppm
ETIM 8.0 EC001603
ETIM 7.0 EC001603
PU (SPU) 1 pcs
Packaging type box
Country of origin DE
GTIN 4055143889827
Customs tariff number 8537109160
Environmental Product Compliance
CAS-No. 1314-23-4
1317-36-8
693-98-1
7439-92-1
79-94-7
REACH Candidate List Substance 2,2',6,6'-tetrabromo-4,4'-isopropylidenediphenol
2-methylimidazole
Lead
Lead monoxide
Zirconium Oxide
RoHS Compliance Status Compliant,With Exemption
RoHS Exemption 7(a)
7(c)-I
7(c)-II
SCIP notification number (Austria) 59c453fd-70c4-4e47-b49d-8defb2a7ccef
SCIP notification number (Belgium) 1c66d48e-1702-40e1-bf5e-b8bdec11ddee
SCIP notification number (Bulgaria) bd8609cf-ee48-45ea-a0d7-47b44ed2126c
SCIP notification number (Czech Republic) 5ad1b193-b252-428e-86d7-3fa4f6062798
SCIP notification number (Denmark) 5812fd50-e573-449e-a93a-b4f504284823
SCIP notification number (Finland) 56990278-77b2-4a0b-b0b3-cf4a928add02
SCIP notification number (France) 521957da-c3a3-4dad-8385-702e91ec72a5
SCIP notification number (Germany) 92d75989-0819-4a59-b0d8-3e2cc5b6d2a2
SCIP notification number (Hungary) fef60e02-fb4c-4dc4-8d09-04cd04fa138a
SCIP notification number (Italy) 62a7f694-5ac0-4536-9f00-40fdf0f55727
SCIP notification number (Netherlands) 53257eb2-f811-40ba-95c6-04f52ec82152
SCIP notification number (Poland) 6d189cf5-f37e-41ab-97c0-d9b46d1f5fb8
SCIP notification number (Romania) 2b719490-5c85-48ea-b7d0-8dd3a043cd90
SCIP notification number (Sweden) fe1f1e91-711a-4335-a2e9-81f099e87b6b