WAGO 750-377 Fieldbus Coupler PROFINET IO 750-377 I/O System PLC Modules In Stock
Communication PROFINET IO
Device-specific Supported profiles: PROFIsafe V2, PROFIenergy V1.0; ID code: Vendor ID: 0x011D; Device ID: 0x02EE; Module ID: 0x01000177 (firmware version 01, 02), 0x02000177 (from firmware version 03)
Baud rate 10/100 Mbit/s (10 Mbit/s (ETHERNET protocols), 100 Mbit/s full duplex (PROFINET IO))
Bus segment length (max.) 100 m
Transmission medium Twisted Pair S-UTP; 100 Ω; Cat. 5
Number of modules per node (max.) 64
Input and output process image (fieldbus) max. 256 bytes/256 bytes
Supply voltage (system) 24 VDC (-25 … +30 %); via pluggable connector
Current consumption (5 V system supply) 450mA
Total current (system supply) 700mA
Input current (typ.) at nominal load (24 V) 280mA
Power supply efficiency (typ.) at nominal load (24 V) 90%
Isolation 500 V system/field
Connection data of WAGO 750-377 Fieldbus Coupler PROFINET IO 750-377 I/O System PLC Modules In Stock
Connection technology: communication/fieldbus PROFINET IO: 2 x RJ-45
Connection technology: system supply 2 x CAGE CLAMP®
Connection technology: device configuration 1 x Male connector; 4-pole
Connection type 1 System supply
Solid conductor 0.08 … 1.5 mm² / 28 … 14 AWG
Fine-stranded conductor 0.08 … 1.5 mm² / 28 … 14 AWG
Strip length 5 … 6 mm / 0.2 … 0.24 inches
Physical data
Width 49.5 mm / 1.949 inches
Height 96.8 mm / 3.811 inches
Depth 71.9 mm / 2.831 inches
Depth from upper-edge of DIN-rail 64.7 mm / 2.547 inches
Mechanical Data
Mounting type DIN-35 rail
Color light gray
Housing material Polycarbonate; polyamide 6.6
Fire load 1.406MJ
Weight 107.1g
Conformity marking CE
Environmental requirements
Ambient temperature (operation) 0 … +55 °C
Ambient temperature (storage) -25 … +85 °C
Protection type IP20
Pollution degree 2 per IEC 61131-2
Operating altitude 0 … 2000 m / 0 … 6562 ft
Mounting position horizontal (standing/lying); vertical
Relative humidity (without condensation) 95%
Vibration resistance 4g per IEC 60068-2-6
Shock resistance 15g per IEC 60068-2-27
EMC immunity to interference per EN 61000-6-2, marine applications
EMC emission of interference per EN 61000-6-3, marine applications
Exposure to pollutants Per IEC 60068-2-42 and IEC 60068-2-43
Permissible H2S contaminant concentration at a relative humidity 75 % 10ppm
Permissible SO2 contaminant concentration at a relative humidity 75 % 25ppm
Product Group 15 (I/O System)
eCl@ss 10.0 27-24-26-07
eCl@ss 9.0 27-24-26-07
ETIM 8.0 EC001603
ETIM 7.0 EC001603
PU (SPU) 1 pcs
Packaging type box
Country of origin DE
GTIN 4050821687443
Customs tariff number 85176200000
Environmental Product Compliance
CAS-No. 1317-36-8
693-98-1
7439-92-1
REACH Candidate List Substance 2-methylimidazole
Lead
Lead monoxide
RoHS Compliance Status Compliant,With Exemption
RoHS Exemption 6(c)
7(a)
7(c)-I
7(c)-II
SCIP notification number (Austria) 8e50993b-352f-4caf-b004-7e9bce6f15bb
SCIP notification number (Belgium) a14f6ab6-06ac-4c61-98a2-5c189db49153
SCIP notification number (Bulgaria) 2a37af0c-f34d-4aed-afec-3f07e855fd3a
SCIP notification number (Czech Republic) 4533a93d-d469-4c73-8f02-f71b1d908549
SCIP notification number (Denmark) d80e9460-6e10-4c56-9fe2-521065092b5a
SCIP notification number (Finland) a863a644-f00a-44c2-8803-845c28ed6d3a
SCIP notification number (France) d2bd405c-a678-4596-9082-85dc4e946173
SCIP notification number (Germany) 92183a6e-26ea-470d-aff7-cc025a1b5463
SCIP notification number (Hungary) b146cca2-9aec-44c2-9ab9-34650969996e
SCIP notification number (Italy) c2952b09-a026-4fb2-bdc1-29d0d10f0151
SCIP notification number (Netherlands) 1184562c-de93-4a45-ad62-0783d6050495
SCIP notification number (Poland) 566db317-8dbc-4015-b228-7d4e34300976
SCIP notification number (Romania) b746bece-b994-46d0-be97-e360b08af70e
SCIP notification number (Sweden) 8583835a-b794-43b9-92a9-38cb252241c7