The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.
By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.
YTA610 features include:
Dual-compartment field-mount housing
Choice of HART 7, or FOUNDATION™ Fieldbus ITK 6 Protocol
Local Parameter Setting function (Indicator model)
Basic diagnosis
Input Signals
Input number: single and dual input
Input type is selectable: Thermocouples, 2-, 3-, and
4-wire RTDs, ohms and DC millivolts.
See Table 1. on page 4.
Input Signal Source Resistance (for T/C, mV)
1 kΩ or lower
Input Lead Wire Resistance (for RTD, ohm)
10 Ω per wire or lower
Span & Range Limits
See Table 1. on page 4.
Output Signals
Two wire 4 to 20 mA DC type
Output range: 3.68 to 20.8 mA DC
HART protocol is superimposed on the 4 to 20 mA
signal.
Fieldbus type
Output signal based on FOUNDATION Fieldbus
communication protocol.
Isolation
Input/Output/GND isolated to 500V DC
Except lightning protector option.
Manual Test Output Function
The output value can be set manually.
Sensor Burnout (HART type)
High (21.6 mA DC) or Low (3.6 mA DC), user
selectable.
Output in Transmitter Failure (HART type)
Down-scale: –5%, 3.2 mA DC or less (Optional code
C1 or C2)
Up-scale: 110%, 21.6 mA DC or more (Standard or
Optional code C3)
Update Time (HART type)
Approximately 0.5 seconds for a single sensor (0.8
second for dual sensors)
Turn-on Time (HART type)
Approximately 6 seconds for a single sensor (7
seconds for dual sensors)
Damping Time Constant
Selectable from 0 to 100 seconds
Self-Diagnostics
Self-diagnostic function based on the NAMUR NE107
standard detects failures.
Hardware-Diagnostics
Hardware failure: Detect in CPU, ADC, Memory, etc.
Sensor-Diagnostics
Sensor failure: Detect the disconnection of sensor.
Sensor line information: Measure the line resistance.
Sensor drift: Detect the difference between sensor1
and sensor2.
Fieldbus Functions (Fieldbus type)
Functional specifications for Fieldbus communication
conform to the standard specifications (H1) of
FOUNDATION Fieldbus.
About OpreX
OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.