YOKOGAWA YTA610‐JA1A4DDKU2 YTA610 Series Temperature Transmitter

YOKOGAWA YTA610‐JA1A4DDKU2 YTA610 Series Temperature Transmitter

  • Product Item : YTA610‐JA1A4DDKU2
  • Product Brand : Yokogawa
  • INQUIRY

YOKOGAWA YTA610‐JA1A4DDKU2 YTA610 Series Temperature Transmitter

The YTA610 provides high accuracy, stability, and reliability. The housing structure adopts reliable dual-compartment structure. The sensor input can be choice of single or dual inputs. This input can accept the RTD, thermocouple, ohm, or DC millivolt. It converts the sensor input to a 4 to 20 mA DC analog signal or Fieldbus digital signal. HART 7 Protocol or FOUNDATION™ Fieldbus ITK 6 version are available. The dual input can accept two sensors calculation of the differential or average value and the sensor backup function. Sensor backup functions for automatically switches-over from the primary to the backup upon sensor failure.

By adoption of local parameter switch on the Indicator, it becomes easy to do the on-site setting work.

YTA610 features include:

Dual-compartment field-mount housing

Choice of HART 7, or FOUNDATION™ Fieldbus ITK 6 Protocol

Local Parameter Setting function (Indicator model)

Basic diagnosis

FUNCTIONAL SPECIFICATIONS YOKOGAWA YTA610‐JA1A4DDKU2

Input Signals

Input number: single and dual input

Input type is selectable: Thermocouples, 2-, 3-, and

4-wire RTDs, ohms and DC millivolts.

See Table 1. on page 4.

Input Signal Source Resistance (for T/C, mV)

1 kΩ or lower

Input Lead Wire Resistance (for RTD, ohm)

10 Ω per wire or lower

Span & Range Limits

See Table 1. on page 4.

Output Signals

Two wire 4 to 20 mA DC type

Output range: 3.68 to 20.8 mA DC

HART protocol is superimposed on the 4 to 20 mA

signal.

Fieldbus type

Output signal based on FOUNDATION Fieldbus

communication protocol.

Isolation

Input/Output/GND isolated to 500V DC

Except lightning protector option.

Manual Test Output Function

The output value can be set manually.

Sensor Burnout (HART type)

High (21.6 mA DC) or Low (3.6 mA DC), user

selectable.

Output in Transmitter Failure (HART type)

Down-scale: –5%, 3.2 mA DC or less (Optional code

C1 or C2)

Up-scale: 110%, 21.6 mA DC or more (Standard or

Optional code C3)

Update Time (HART type)

Approximately 0.5 seconds for a single sensor (0.8

second for dual sensors)

Turn-on Time (HART type)

Approximately 6 seconds for a single sensor (7

seconds for dual sensors)

Damping Time Constant

Selectable from 0 to 100 seconds

Self-Diagnostics

Self-diagnostic function based on the NAMUR NE107

standard detects failures.

Hardware-Diagnostics

Hardware failure: Detect in CPU, ADC, Memory, etc.

Sensor-Diagnostics

Sensor failure: Detect the disconnection of sensor.

Sensor line information: Measure the line resistance.

Sensor drift: Detect the difference between sensor1

and sensor2.

Fieldbus Functions (Fieldbus type)

Functional specifications for Fieldbus communication

conform to the standard specifications (H1) of

FOUNDATION Fieldbus.

About OpreX

OpreX is the comprehensive brand for Yokogawa’s industrial automation (IA) and control business and stands for excellence in the related technology and solutions. It consists of categories and families under each category. This product belongs to the OpreX Field Instruments family that is aligned under the OpreX Measurement category.

Temperature measuring instrument lineup