ABB Head-mount temperature transmitter TTH200
The TTH200 is provided for all HART standard applications in temperature measurement with one sensor input. The transmitter follows NAMUR Recommendations such as NE 89 and NE 107. The TTH200 supports the same functionality as the TTH300, but without sensor redundancy and sensor drift monitoring. As an option, an LCD indicator can be connected.
The transmitter can be configured with ABB-tools such as Field Information Manager (FIM), with DAT200 (Asset Vision Basic) via DTM, with a Handheld via EDD, or with any standard tool using FDI-/FDT-Technology.
Data
Universal sensor input
– RTD, thermocouple, Ω, mV
Functional safety SIL 2 / SIL 3 in accordance with IEC 61508
Various sensor error-calibration possibilities
– One point, two point, Callendar-van Dusen, freestyle characteristics with 32 supporting points
Output signal
– 4 to 20 mA, HART 5 and HART 7 (switchable)
Accuracy 0.1 %, long-term stability 0.05 % per year
Wire break / corrosion monitoring in accordance with NE 89
Device status signaling and freely configurable diagnostic categorization with diagnostic history according to NE 107
Event monitor for logging critical events
Configuration monitor for configuration changes
Turnable LCD indicator for optimal readability (option)
Approvals for explosion protection
– ATEX, IECEx, zone 0
– FM / CSA
– EAC, EAC-Ex
– NEPSI
TTH300-E1H
TTH300-Y0-H-BS-M
TTH300-E1-H-BS-M
TTH300-E2-H-BS-M
TTH200-Y0S2A1A02A4Y0N1S1P2B2B2H6/OPT
TTH200-E1
TTH200-E1HBFEMGHAM5
TTH200-E1HBFEMD3SF
TTH200.Y0.H.BS
TTH200-E1-H-BS
TTH200-Y0-H-BS/M5.SF
TTH200-E1
TTH200-Y0-H-BS/M5.SF
TTH200-E1-H-BS-C6-EM-GHA-M5
TTH200-C1-H-BS-C6-EM-GHA-M5
TTH200 Y0-H-BS-M5
TTH200-E1-H-BS-C6-EMGHA-M5
TTH200-E1-H-BS
TTH200-E1H - PTB05 ATEX 2017X
TTH200.Y0.H.BS
TTH200-E1H - PTB05 ATEX 2017X
TTH200-Y0-H-B5-CS-EM-GHE-H1-D3-M5
TTH200.E1.H.BF.CS.EM.GHA.D3
TTH200-Y0S2A1A02A4Y0N1S1P2B2B2H6/OPT
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200.E1.H.BF.CS.EM.GHA.D3SFM5
TTH200E1HBFEMGHAM5
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200-E1-H-BS-CS-EM-SE-M5
TTH200-C1-HBS-C6-EM-CHA-M5
TTH200-E1-H-BS
TTH200-E1-H-BS-CS-EM-SE-M5, PT100, 3 WIRE HART
TTH200E1
TTH200-E1-H-BS-C6-EM-GHA-M5
TTH200-E1
TTH200.Y0.H.BS.D3
TTH200.Y0.H.BS
TTH200Y0HBFEMGHEM5
TTH200-Y0
TTH200.E1.H.BF.CS.EM.GHA.D3.SF.M5
TTH200-Y0-H-BS-M5
TTH200.E1.H.BF.EM.D3.SF
TTH200-E1-H-BS-CS-EM-GHE-M5
TTH200-E1H-PTB 05 ATEX 2017 X
TTH200.YO.H.BS
TTH200.Y0.H.BS
TTH200-E1 , HART
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200.Y0.H.BS
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200-Y0-H-BS-CS-EP-GHA-H7-D3-SF-M
TTH200.E1/OPT
TTH200-Y0HBS-EM.M5
TTH200Y0H+7C201
TTH200 Y0
TTH200.E1.H.BF.CS.EM.GHA..D3.SF.M5
TTH200-YO/OPT
TTH200.E1.H.BF.CS.EM.GHA.D3SFM5
TTH200-Y0-H-BS
TTH200-E1.H
TTH200-C1-H-BS-C6-EM-GHA-M5
TTH200-E1/OPT (RTD WIRE )
TTH200.E1.H.BS
TTH200-C1-H-BS-C6-EM-CHA-M5
TTH200.E1.H.BF.CS.EM.GHA..D3.SF.M5
TTH200.Y0-H-BS-M5
TTH200 E1 H BS CS EM SE M5
TTH200-S1.H
TTH200Y0H
TTH200-Y0-H-BS