Welcome to CW Green Tech Limited
[email protected] 86-136 6712 1125
Home      Products Yokogawa EJX530A In-Line Mount Gauge Pressure Transmitter
Yokogawa EJX530A In-Line Mount Gauge Pressure Transmitter

Yokogawa EJX530A In-Line Mount Gauge Pressure Transmitter

  • Product Item : EJX530A
  • Product Brand : Yokogawa
  • INQUIRY

Yokogawa EJX530A In-Line Mount Gauge Pressure Transmitter

The EJX530A is the gauge-connected relative pressure transmitter in the series.

Part Number: EJX530A-JBS4N-017EL/FU1/X2  EJX530A-DAS4N-012NN

Model: EJX530A Gauge Pressure Transmitter

Brand: Yokogawa

Condition: New & Original in Factory Packing

Factory Warranty: 12 Months

The EJX-A series is Yokogawa's premium product line. Launched in 2004, the device offers the performance and stability required for particularly demanding applications.

The EJX-A series includes the high-end transmitters of the DPharp product family.

EJX530A standard features:

±0.04% measurement accuracy

±0.1% stability over 15 years

90 ms response time

Certified according to Exida and TüV SIL 2/SIL 3

Local parameter setting (LPS)

Plants run better with Yokogawa differential pressure transmitters.

At it's heart, Yokogawa's differential pressure transmitter with DPharp digital sensor offers the performance and device intelligence needed to get greater insight into your process.

Specifications of Yokogawa EJX530A In-Line Mount Gauge Pressure Transmitter

Measurement Types

Primary Variable: Absolute Pressure

Reference Accuracy Primary Variable: ±0.04% of Span

Stabilit  Primary Variable: ±0.1% of URL per 10 years

Response Time

Primary Variable: 90ms

Rangeability

Primary Variable: A Capsule: 25:1  B, C, or D Capsule: 50:1

Burst Pressure (Absolute) A, B, or C Capsule: 4,350 psi (30 MPa) D Capsule: 19,100 psi (132 MPa)

Specification Conformance EJX-A Series: ±3s

Other models of EJX530A Gauge pressure transmitter, selection list

Model  Suffix Codes  Description

Output signal

D---4 to 20 mA DC Output with digital communication (BRAIN protocol)

E---4 to 20 mA DC Output with digital communication (HART protocol)

F---Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C25T02-01E)

Measurement span (Capsule)

A---8 to 200 kPa (1.16 to 29 psi)     B---0.04 to 2 MPa (5.8 to 290 psi)

C---0.2 to 10 MPa (29 to 1450 psi)    D---1 to 50 MPa (145 to 7200 psi)

Process connection Diaphragm

S---316L SST Hastelloy C-276 *1

H---Hastelloy C-276 *1 Hastelloy C-276 *1

Process connections

4---1/2 NPT female    7---1/2 NPT male  8---G1/2 DIN 16 288 male *2

9---M20 1.5 DIN 16 288 male *2   N---Always N  0---Always 0

Amplifier housing

1---Cast alluminum alloy

Electrical connection

0---G1/2 female, one electrical connection without blind plugs

2---1/2 NPT female, two electrical connections without blind plugs

4---M20 female, two electrical connections without blind plugs

5---G1/2 female, two electrical connections with a blind plug

7---1/2 NPT female, two electrical connections with a blind plug

9---M20 female, two electrical connections with a blind plug

Integral indicator

D---Digital indicator    N---None

E---Digital indicator with the range setting switch *3

Mounting bracket

F ---304 SST 2-inch pipe mounting   N ---None

The most typical selection for each specification. Example: EJX530A-DAS4N-012NN/.

*1: Hastelloy C-276 or ASTM N10276.

*2: Not applicable for combination of capsule code D and wetted parts material code H.

*3: Not applicable for output signal code F.

*4: Users must consider the characteristics of selected wetted parts material and influence of process fluids. Specifying

inappropriate materials has the potential to cause serious damage to human body and plant facilities resulted from an