  • Product Item : EDS-308-SS-SC
  • Product Brand : Moxa
  • INQUIRY

Here is the parameter introduction of EDS-308-SS-SC:


  • Port Configuration

  • Port Type: 10/100BaseT(X)/FX1.

  • Port Quantity: 8 ports, including 6 RJ45 - interface 10/100BaseT(X) ports and 2 single - mode SC - interface 100BaseFX ports4.

  • Network Standards4: It complies with IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X) and 100BaseFX, and IEEE 802.3x for flow control.

  • Switch Properties

  • MAC Table Size: 2 kbits.

  • Packet Buffer Size: 768 k.

  • Processing Type: Store - and - forward.

  • Ring Redundancy and VLAN1: It has no ring redundancy and supports VLAN function.

  • Management and Alarm Functions1: It has no network management function. The alarm function is realized by a relay, which can send out warnings for power failure and port break alarm.

  • Optical Fiber Parameters

  • Fiber Cable Type: For 100BaseFX, it supports multi - mode OM1 50/125 µm fiber and single - mode G.652 fiber.

  • Typical Transmission Distance: Multi - mode fiber is 4 km, and single - mode fiber is 40 km or 80 km.

  • Wavelength: TX wavelength range is 1260 - 1360 nm for multi - mode, 1280 - 1340 nm for 40 - km single - mode, and 1530 - 1570 nm for 80 - km single - mode. RX wavelength range is 1100 - 1600 nm for all.

  • Optical Power: TX power range is - 10 to - 20 dBm for multi - mode, 0 to - 5 dBm for single - mode. RX sensitivity range is - 3 to - 32 dBm for multi - mode, - 3 to - 34 dBm for single - mode. The link budget is 12 dB for multi - mode and 29 dB for single - mode. The dispersion penalty is 3 dB for multi - mode and 1 dB for single - mode.

  • Power Parameters

  • Input Current: 0.15 A @ 24 VDC.

  • Operating Voltage: 9.6 - 60 VDC. It supports redundant dual - input power, with input voltages of 12/24/48 VDC, and also supports reverse - polarity protection and overload - current protection. The power connector is a removable 6 - contact terminal block.

  • Physical Characteristics

  • Housing: Metal, with an IP30 protection rating.

  • Dimensions: 53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in).

  • Weight: 790 g (1.75 lb).

  • Installation: It can be installed on a DIN - rail or on a wall (with an optional kit).

  • Environmental Limits

  • Operating Temperature: - 10 - 60 °C (14 - 140 °F).

  • Storage Temperature: - 40 - 85 °C (- 40 - 185 °F).

  • Ambient Relative Humidity: 5% - 95% (non - condensing).

  • Standards and Certifications

  • Safety: UL 508, UL 60950 - 1, CSA C22.2 No. 60950 - 1, EN 62368 (LVD).

  • EMC: EN 55032/35. EMI: CISPR 32, FCC Part 15B Class A. EMS: IEC 61000 - 4 - 2 ESD (contact: 6 kV, air: 8 kV), IEC 61000 - 4 - 3 RS (80 MHz - 1 GHz: 20 V/m), IEC 61000 - 4 - 4 EFT (power: 2 kV, signal: 1 kV), IEC 61000 - 4 - 5 Surge (power: 2 kV, signal: 2 kV), IEC 61000 - 4 - 6 CS (10 V).

  • Hazardous Locations: ATEX Class I Division 2.

  • Maritime: DNV.

  • MTBF: 2,382,553 hrs according to MIL - HDBK - 217F standard.

  • Warranty: The warranty period is 5 years.