  • Product Item : 6DL1134-6GH00-0PH1
  • Product Brand : Siemens
  • INQUIRY

6DL1134-6GH00-0PH1

Here are the parameters of 6DL1134 - 6GH00 - 0PH1:


  • General Information

  • Product Model: 6DL1134 - 6GH00 - 0PH1

  • Product Type: SIMATIC ET 200SP HA Analog Input Module, AI 8xI 2 - / 4 - wire HART HA

  • Firmware Version: Updatable

  • Compatible Terminal Blocks: H1, M1

  • Color Code: CC01

  • I&M Data: Available (I&M0 - I&M3)

  • Compatibility with Software: Configurable in STEP 7 TIA from V16, STEP 7 from V5.6, PCS 7 from V9.0, PCS neo from V3.0. PROFINET: GSDML V2.3

  • Power Supply

  • Rated current consumption without load: 75 mA

  • Maximum current consumption without load: 100 mA

  • Rated Voltage (DC)3: 24 V

  • Allowable Voltage Range (DC)3: 19.2 V - 28.8 V

  • Reverse - Polarity Protection: Yes

  • Power Consumption:

  • Analog Input

  • Linearity error: [Value related to the input range, e.g., ±0.01%]

  • Temperature error: [Value related to the input range, e.g., ±0.0009% / K]

  • Number of Channels: 8

  • Input Type: Current input, 2 - wire / 4 - wire HART

  • Input Range: [Specific range, e.g., 0 - 20 mA, 4 - 20 mA]

  • Resolution: [Typical value, e.g., 16 bits]

  • Conversion Time: [Typical value, e.g., 60 ms per channel]

  • Measurement Value Filtering: Parameterizable (None, Weak, Medium, Strong, selectable per channel)

  • Error / Accuracy:

  • Diagnostic Function3

  • MAINT LED(yellow)

  • Power supply voltage monitoring(PWR - LED, green)

  • Channel status display(green LED)

  • Channel diagnostic LED(red)

  • Module diagnostic LED(green / red)

  • Diagnostic Function: Yes

  • Alarms: Diagnostic alarms and limit value alarms (two upper and two lower limits respectively)

  • Diagnostic Information: Readable. Power supply voltage monitoring, open - circuit detection for each channel, and overflow / underflow detection

  • Diagnostic Display LEDs:

  • Potential Isolation3

  • Potential Separation between Channels: No

  • Potential Separation between Channels and Backplane Bus: Yes

  • Potential Separation between Channels and Load Voltage L +: Yes

  • Environmental Requirements3

  • Horizontal installation: - 40 °C - 70 °C

  • Vertical installation: - 40 °C - 60 °C

  • Operating Temperature:

  • Storage Temperature: - 40 °C - 85 °C

  • Relative Humidity: 5% - 95% non - condensing

  • Dimensions and Weight3

  • Width: 22.5 mm

  • Height: 115 mm

  • Depth: 138 mm