Welcome to CW Green Tech Limited
[email protected] 86-136 6712 1125
Home      Products MEANWELL LRS-200-3.3 switching power supply LRS-200 series
MEANWELL LRS-200-3.3 switching power supply LRS-200 series

MEANWELL LRS-200-3.3 switching power supply LRS-200 series

  • Product Item : LRS-200-3.3
  • Product Brand : Meanwell
  • INQUIRY

Here is the parameter information of MEAN WELL LRS - 200 - 3.3:

Electrical Parameters5

  • Input Voltage: 90 - 132VAC / 180 - 264VAC, selectable by switch. It can also work with 240 - 370VDC (switch on 230VAC).

  • Input Frequency: 47 - 63Hz.

  • Output Voltage: Nominal 3.3VDC, adjustable from 2.97 - 3.6V.

  • Output Current: 40A.

  • Rated Power: 132W.

  • Ripple & Noise: Max. 150mV - P.

  • Voltage Tolerance: ±3.0%.

  • Line Regulation: ±0.5%.

  • Load Regulation: ±2.5%.

  • Efficiency: Typically 83%.

  • AC Current: 4A / 115VAC, 2.2A / 230VAC.

  • Inrush Current: Cold start, 60A / 115VAC, 60A / 230VAC.

  • Leakage Current: Less than 2mA / 240VAC.

  • Physical Characteristics5

  • Dimensions: 215mm (length) x 115mm (width) x 30mm (height).

  • Weight: 0.66kg.

  • Output Connector Type: Usually a screw terminal block.

  • Housing Material: Metallic mesh case for better heat dissipation.

  • Performance Parameters5

  • Operating Temperature Range: - 25°C to + 70°C (refer to the "derating curve").

  • Storage Temperature Range: - 40°C to + 85°C.

  • Operating Altitude: Up to 5000 meters.

  • Vibration Resistance: Withstand 5G vibration test, 10 - 500Hz, 10min / 1 cycle, 60min each along x, y, z axes.

  • Minimum Isolation Voltage: I/P - O/P: 3kVAC; I/P - FG: 2kVAC; O/P - FG: 0.5kVAC.

  • Isolation Resistance: I/P - O/P, I/P - FG, O/P - FG: 100M ohms / 500VDC / 25°C / 70% RH.

  • Protection Functions5

  • Short - circuit Protection: Protects the power supply and connected devices from damage in case of a short circuit.

  • Overload Protection: Protects within the range of 110% - 140% of the rated output power. It adopts hiccup mode and recovers automatically after the fault condition is removed.

  • Over - voltage Protection: Protects the load from being damaged by excessive output voltage. The protection range is about 3.8 - 4.45V. It adopts hiccup mode and recovers automatically after the fault condition is removed.

  • Over - temperature Protection: Activates when the internal temperature of the power supply is too high, preventing damage to components. It adopts hiccup mode and recovers automatically after the fault condition is removed.

  • Other Features

  • LED Indicator: There is an LED indicator for power - on, which allows users to easily check the working status of the power supply.

  • Full - load Burn - in Test: 100% full - load burn - in test is carried out to ensure the reliability and stability of the product.

  • Warranty: 3 - year warranty.

  • Certifications: Complies with international safety regulations such as IEC / UL 62368 - 1, CE, CB, RCM.