Gastron Single Channel Gas Detector Receiver GTC-550
GTC-550 receiver unit adopts the high performance A/D converter and micro-process and is equipped with diverse functions. GTC-550 receiver unit is independent receiver unit connected with one detection unit, protected by case using ABS material and displays the concentration with FND digital display. It has primary alarm, secondary alarm and tertiary alarm function and failure alarm
function.
Model GTC-550
Operation display 6-LED( Power, 3-alarm, Trouble, Stan-by for Maintenance )
Measuring display 3-Digit 1.8” FND
Measuring range 1~999 (Programmable) / %LEL , %volume , ppm
Alarm display
Visual display: 3-Alarm, Trouble LED, Mars light
Audio display: Buzzer signal
Alarm output Signal 3-stage Alarm, Trouble/ AC250V 5A Relay contact(SPDT)
Alarm level set Set the program within measuring range
Input signal 4~20mA DC( 2wire or 3wire)
Output signal
4~20mA DC
Isolated RS-485 Modbus(Option)
Reset signal Reset switch and remote control
Program set mode
Set strength and type of alarm (1,2,3 alarm)
Set time of alarm (immediate & delayed (1~60 sec))
Alarm range (Dead band)
Compensate the measured value (SAD)
Set relay output to on/off
Operating temperature -20℃ ~ +50℃
Operating humidity 0~99%.RH(non-condensing)
Operating power
AC85~260V / 3.6W
24V DC (Option)
Current Consumption
Minimum: 50mA (While the gas concentration is displayed,
gas value 0)
Maximum: 180mA(while gas concentration is displayed, gas
value Over)
(Buzzer: 25mA, Relay: each 20mA for Alarm 1,2,3)
And when the Mars light or product is added, the current
consumption is increased
Dimensions 280 X 389 X 153
Weight 1.98Kg