Welcome to CW Green Tech Limited
[email protected] 86-136 6712 1125
Home      Products PEPPERL+FUCHS Segment Protector R2-SP-IC
PEPPERL+FUCHS Segment Protector R2-SP-IC

PEPPERL+FUCHS Segment Protector R2-SP-IC

  • Product Item : R2-SP-IC
  • Product Brand : Pepperl+Fuchs
  • INQUIRY

PEPPERL+FUCHS Segment Protector R2-SP-IC

4 ... 12 outputs Ex ic (FISCO or Entity) or non-incendive (Div 2)

Advanced fault isolation at the spur

Segment Protector in Zone 2/Div. 2

Instruments in Zone 2/Div. 2 or Zone 1/Div. 1

For FOUNDATION Fieldbus H1 and PROFIBUS PA

Advanced Diagnostics at the spur

Power, Com, Diagnostics, and Error LEDs

T-connector for easy installation and maintenance

Test points for easy troubleshooting

Product Description

Segment protector, junction box for fieldbus with short-circuit and fault protection, field junction box, electronic component for control cabinet installation

General specifications

Design / MountingCabinet installation

Installation in hazardous areaZone 2 / Div. 2

Fieldbus connection

Main cable (Trunk)

Rated voltage9 ... 31 V DC

10.5 V DC minimum input voltage acc. to FF-846

Rated currentmax. 4.5 A

Outputs

Number of outputssee table Technical data depending on model

Number of devices per output1

Rated voltagemax. 31 V

Rated currentmax. 32 mA switch 1, position 1

max. 43 mA switch 1, position 2

Short-circuit current46 mA switch 1, position 1

57 mA switch 1, position 2

Self current consumptionsee table Technical data depending on model

Voltage drop main cable/outputsmax. 1.2 V

Voltage drop trunk In/Out0 V

Terminating resistorexternal type M-FT 100 Ω +/- 10 %

Surge protectionTrunk overvoltage protection if voltage exceeds typ. 39 V, max. 41 V

Indicators/operating means

Switchconfiguration of short-circuit current/rated current

LED PWRgreen: Fieldbus voltage 10 V and fieldbus terminator is deactivated

LED COM/ERRyellow: flashing: fieldbus communication status and physical layer diagnostic status

LED SPURSred: 2 Hz flashing in short-circuit condition

More PEPPERL+FUCHS Segment Protector R2-SP-IC models

KCD2-SR-Ex1.LB ,KCD2-SR-Ex2,KFA6-DU-Ex1.D

KFA6-ER-Ex1.W.LB , KFA6-SOT2-Ex2,KFA6-SR2-Ex1.W

KFA6-SR2-Ex1.W.LB,KFA6-SR2-Ex2.W ,KFA6-SR2-Ex2.W.IR

KFD2-DU-Ex1.D

KFD2-ELD-Ex16 ,KFD2-ER-Ex1.W.LB ,KFD2-SH-Ex1

KFD2-SH-Ex1.T.OP,KFD2-SOT3-Ex1.LB,KFD2-SOT3-Ex1.LB.IO

KFD2-SOT3-Ex2,KFD2-SOT3-Ex2.IO,KFD2-SR2-Ex1.W

KFD2-SR2-Ex1.W.LB

KFD2-SR2-Ex2.W,KFD2-SR3-Ex2.2S,KFD2-SRA-Ex4

KFD2-ST3-Ex1.LB ,KFD2-ST3-Ex2,KHA6-SH-Ex1

KCD2-SON-Ex1,KCD2-SOT-Ex1.LB,KCD2-SOT-Ex2

KCD2-SOT-Ex2.SP

KCD2-SR-Ex1.LB.SP,KCD2-SR-Ex2.SP,KCD2-ST-Ex1.LB

KCD2-ST-Ex2,KFA5-SOT2-Ex2 ,KFA5-SR2-Ex1.W

KFA5-SR2-Ex1.W.LB ,KFA5-SR2-Ex2.W , KFA5-SR2-Ex2.W.IR

KFD2-SH-Ex1.T

KFD2-SOT3-Ex2.IO-Y1 ,KCD2-SON-Ex1.R1,KCD2-SON-Ex1.SP

KCD2-SON-Ex2 ,KCD2-SON-Ex2.R1 ,KCD2-SON-Ex2.SP

KCD2-SOT-Ex1.LB.SP, KCD2-ST-Ex1.LB.SP ,KCD2-ST-Ex2.SP

KFA4-SR2-Ex2.W