Max. measurement error
Flow: ±5 % o.f.s.
Measuring range
226 to 14 100 000 l/h (60 to 3 730 000 gal/h)
(under reference conditions)
Medium temperature range
–20 to +100 °C (–4 to +212 °F)
Max. process pressure
PN 40
Wetted materials
Transducer: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Insertion tube: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection:
‐ Compression fitting: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Threadolet: 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Clamping ferrule: PEEK 450G; 1.4404 (316L); Alloy C22, 2.4602 (UNS N06022)
‐ Tri‐Clamp; DN40 DIN 11851, DN50 DIN 11851; DN40 DIN 11864‐1A, DN50 DIN 11864‐1A: 1.4404 (316L)
The t-mass T 150 is the first thermal mass device from Endress+Hauser for measuring liquids. t-mass T 150 is designed chiefly for water applications. As it measures independently of the electrical conductivity of a fluid and can be used in a variety of water-based and non-water-based liquids for the purpose of monitoring and trending. Customer-specific settings are saved on the display and can be transferred from one device to another by means of the display.
Measuring principle is characterized by a high operable flow range and direct mass flow measurement
Dedicated to the monitoring of conductive and non-conductive liquids.
Device properties
Insertion version for nominal diameter DN 40 to 1000 (1 1/2 to 40")
Sensor in standard or hygienic version
SIP cleaning possible up to 130 °C (266 °F)
Device in compact version with DC 24 V power supply
4-20 mA HART, pulse/frequency/switch output
Compact and robust transmitter
Flexible, convenient programming based on 21 standard gases or freely definable gas mixtures thereof
High level of process control – premium measurement accuracy and repeatability
Reliable monitoring – detection of process disturbances and reverse flow
Easy maintenance – removable sensor
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Proline t-mass A 150 thermal mass flowmeter
Proline t-mass B 150 thermal mass flowmeter
Proline t-mass F 500 thermal mass flowmeter
Proline t-mass I 300 thermal mass flowmeter
Proline t-mass I 500 thermal mass flowmeter
Proline t-mass T 150 thermal mass flowmeter
Flowphant T DTT31 Flow switch
Flowphant T DTT35 Flow switch